Select "Extract Here" or "Extract to [KS] KS4 GP03/" to view the files.
Once the peak value is established at 40, set the Alert threshold to trigger at a value slightly above this peak to ensure you are notified of actual knock events. 3. Using the GP-03 Component
Use the setup program on your PC to modify settings such as Bump Fail Behavior or Auto Zero Adjustment .
Adjust the settings until the peak readings display approximately 40 on the device's scale.
Ensure the engine is operating correctly and the KS-4 alerts are turned OFF before starting the configuration.
To access the files within a .rar archive, you must use extraction software like WinRAR or 7-Zip. Download and install a compatible extractor. Step 2: Right-click the KS4 GP03.rar file.
Adjust the bandwidth setting to match your engine's expected knock frequency. Calibrate Gain: